Thermal & Mechanical Analysis

Lab's Equipment List

  1. Netzsch 409C TGA PerkinElmer
  2. Pyris Diamond TGA
  3. TA Instrument SDT Q600 TGA
  4. PerkinElmer Diamond DSC
  5. Mettler Toledo 822e DSC
  6. Elementar Vario EL III Elemental Analyser
  7. TA RSA3 DMA
  8. Instron 5543 Tensile Meter

Thermal Gravimetric Analysers
[Pyris Diamond TGA (Perkin Elmer) ]


Thermal Gravimetric Analysers [SDT Q600 TGA (TA Instruments)]

Key features of Thermal Gravimetric Analysers

  • Temperature range from ambient to 1100, 1200 and 1500 ˚C
  • Heating Rate up to 50 K/min
  • Sample weight typically 1-5 mg
  • Automatic gas switching for nitrogen or air
  • Sample Pans using platinum and alumina
  • Furnace Cooling Forced Air or Chiller

Location: N1.2-B4-13
Contact email: TTOng@ntu.edu.sg

Thermal Gravimetric Analysers [NETZSCH 409C TGA]

Key features of Thermal Gravimetric
Analyser

  • Temperature range from ambient to 1100, 1200 and 1500 ˚C
  • Heating Rate up to 50 K/min
  • Sample weight typically 1-5 mg
  • Automatic gas switching for nitrogen or air
  • Sample Pans using platinum and alumina
  • Furnace Cooling Forced Air or Chiller
Location: N1.3-B3-22
Contact email: SCYu@ntu.edu.sg


Differential Scanning Calorimeters (DSC) Mettler Toledo 822e

Key features for Mettler Toledo 822e DSC

  • With liquid nitrogen cooling operation
  • Temperature range: -150 – +500 oC
  • 200W furnace with a max heating rate of 20 K/min
  • N2 protective gas purge
Location: N1.2-B3-06
Contact email: WangXJ@ntu.edu.sg


Differential Scanning Calorimeters (DSC) PerkinElmer Diamond

Key features of PerkinElmer Diamond DSC

  • Temperature range -30 oC to 730 oC
  • Heating rate 0.01 K to 500 K/min
Location: N1.3-B3-22
Contact email: SCYu@ntu.edu.sg


Vario EL III CHNS Elemental Analyser (EA)

Key features of Vario EL III CHNS Elemental Analyser (EA)

  • Operation modes are CHNS or CHN
  • Analysis of C, H, N or S
  • Sample weight is typically 5 mg
  • Accuracy up to 5%
  • Calibration: matrix-free, multiple-point calibration, long term stability
  • 79-position auto sampler
  • Digestion temperatures at 950 - 1200 C
  • Analysis time is self-adjusting
Location: N1.2-01-03
Contact email: TTOng@ntu.edu.sg


5543 Tensile Meter

Key features of 5543 Tensile Meter

  • Measurement modes are tension or compression
  • Load capacity max. 1000 N
  • Load cells are 10 N, 100 N
  • Grips are 10 N, 100 N
  • Measurement speed is 0.05-1000 mm/min
Location: N1.2-B1-33
Contact email: TTOng@ntu.edu.sg


TA RSA3 DMA

Key features of TA RSA3 DMA

  • Temperature range ambient to 500 degree C
  • Temperature ramp rate 0.1 degree to 50 degree C/min
  • Motor max force: 35 N (3500 g), strain resolution +/-0.05 u
Location: N1.2-B2-11
Contact email: WangXJ@ntu.edu.sg